The location of fault-related sidebands in the motor current spectrum is determined by slip frequency, not by fixed values. This calculator computes the exact frequencies for your motor's operating conditions, so you know precisely where to look.
The Science of MCSA Fault Frequencies
Motor Current Signature Analysis (MCSA) detects mechanical and electrical faults by analyzing the frequency content of the stator current waveform. A healthy induction motor draws current at the supply frequency (50 or 60 Hz). Faults: particularly rotor asymmetries: create magnetic flux disturbances that modulate this fundamental frequency, producing characteristic sidebands in the current spectrum.
Slip is the difference between the rotating magnetic field (synchronous speed) and the actual rotor speed, expressed as a fraction. In healthy, lightly loaded motors, slip is typically 1 to 3 percent. As load increases or rotor faults develop, slip rises. Because slip directly sets how far fault sidebands are offset from the supply frequency, you cannot find a fault sideband without knowing the actual running slip for that measurement.
Three fault signatures are computed here. Rotor bar fault sidebands appear symmetrically around the supply frequency at a spacing of twice the slip frequency. A broken or cracked rotor bar disrupts rotor symmetry and appears at these locations. Eccentricity sidebands (from air gap irregularity, whether static misalignment or dynamic shaft bow) appear at offsets equal to the running speed in Hz above and below supply frequency. Rotor slot harmonics arise from the periodic variation in air gap permeance as rotor slots pass the stator poles; these appear at the rotor slot passing frequency plus and minus the supply frequency.
All of these frequency values are mathematically exact given correct inputs. Diagnosis, however, requires trending amplitude over multiple measurements. The presence of a frequency component is expected; a rising amplitude compared to baseline is the indicator of a developing fault.
Formulas
s = (Ns - Nr) / Ns // Per-unit slip (dimensionless)
fs = s × f₁ // Slip frequency (Hz)
// Rotor bar fault (broken bar) sidebands
f_BRB_lower = f₁ × (1 - 2s) // Hz
f_BRB_upper = f₁ × (1 + 2s) // Hz
// Eccentricity sidebands (1× running speed)
f_ECC_lower = f₁ - (Ns / 60) // Hz
f_ECC_upper = f₁ + (Ns / 60) // Hz
// Rotor slot harmonics (if Nb known)
f_RSH = (Nb × Nr / 60) ± f₁ // Hz: two values
Calculator
Interpreting the Results
Rotor Bar Fault Sidebands
A broken or cracked rotor bar creates an asymmetry in the rotor circuit. This generates a backward-rotating flux component that, when combined with the forward-rotating supply field, produces current components at f₁(1 - 2s) and f₁(1 + 2s). In a healthy motor these sidebands exist at low amplitude from inherent asymmetries. A rising amplitude trend in the lower sideband especially is the diagnostic indicator. IEEE recommends comparing amplitude in dB relative to the fundamental across multiple measurement intervals.
Eccentricity Sidebands
Eccentricity refers to a non-uniform air gap between rotor and stator. Static eccentricity (fixed position offset) and dynamic eccentricity (rotor centerline orbiting the geometric center) both produce sidebands at running speed offsets from supply frequency. The offset equals the mechanical running frequency in Hz, which is the synchronous speed divided by 60. Because these sidebands are close to the fundamental, a high-resolution spectrum analyzer with narrow frequency spans is required to resolve them cleanly.
Rotor Slot Harmonics
As rotor slots pass beneath the stator poles, the air gap permeance varies periodically. This creates a high-frequency component at the rotor slot passing frequency (Nb × Nr / 60), with sidebands offset by the supply frequency. These harmonics are present in healthy motors: their utility in fault diagnosis is as a reference for validating rotor bar count when manufacturer data is unavailable, and as a check on speed measurement accuracy.
A Note on Slip and Load
Slip changes with load. A motor that runs at 1745 RPM under full load may run at 1790 RPM under light load on the same supply. Because fault sideband frequencies depend directly on slip, measurements taken at different load points will show sidebands at different frequencies. Always record load condition alongside RPM when logging MCSA measurements. Comparing spectra taken at significantly different loads can lead to misidentification of sidebands.